Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kim, Tae-Gon | Lee, Yang-Sun | Kim, Young-Pyo | Park, Yong-Pil | Cheon, Min-Woo
Affiliations: Department of Electrical and Electronic, Dongshin University, Jeonnam Na-Ju, Korea | Division of Computer Engineering, Mokwon University, Daejeon, Korea | Department of Biomedical Engineering, Dongshin University, Jeonnam Na-Ju, Korea
Note: [] Corresponding author: Min-Woo Cheon, Department of Biomedical Engineering, Dongshin University, Jeonnan Na-ju, 520-714, Korea. E-mail: [email protected]
Abstract: Utilization of panoramic X-ray device is getting wider. Panoramic X-ray has low resolution than general X-ray device and it occurs to distortion by deviation of image synthesis. Due to structural problems, it has been used restrictively to identify of tooth structure, not for whole head. Therefore, it designed and produced panoramic X-ray device which is possible to diagnostic coverage can be extended and had to be adjusted interval control between X-ray generator and image processing for whole of Maxillofacia's diagnosis. Produced panoramic X-ray device is composed basically of short image synthesis. In addition, it was confirmed the results by used the device which was applied deviation of the brightness of the image, filter to improve the location of the deviation and interpolation method. In this study, it was used 13 images including the front. It occurs to brightness deviation, position deviation, and geometric correction when synthesis of image, but it had been solved by deviation improvement software and a change of CCD camera's scan line which is used for image acquisition. Therefore, it confirmed expansion possibility of utilization range to commonly used panoramic X-ray device.
Keywords: Image processing unit, panoramic X-ray, image compensation, image correction
DOI: 10.3233/XST-140431
Journal: Journal of X-Ray Science and Technology, vol. 22, no. 3, pp. 361-368, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]