Article type: Research Article
Authors: Weir, Victor J. | Zhang, Jie | Bruner, Angela P.
Affiliations: Baylor Health Care System, Dallas, TX, USA | Department of Radiology, University of Kentucky, Lexington, KY, USA
Note: [] Corresponding author: Victor J. Weir, Texas Licensed Medical Physicist (Diagnostic Radiological Physics), Medical Physics & Radiation Safety, Baylor Health Care System, 4005 Crutcher Street, Suite 330, Dallas, TX 75246, USA. Tel.: +1 214 820 8516; E-mail: [email protected]
Abstract: PURPOSE: Patient radiation dose during Computed Tomography (CT) guided biopsy procedures is determined by both acquisition technical parameters and physician practice. The potential effect of the physician practice is of concern. This study is to investigate the effects of those intangibles on patient radiation dose. METHODS: Patient radiation dose from 252 patients who underwent CT guided biopsy from 2009 to 2010 were retrospectively studied. Ten physicians who used conventional intermittent shots, low mA dose saving feature, or both were included in the study. The patient dose reports were retrieved and the total dose length products (DLPs) were analyzed. Linear regression analysis performed between various variables and reported dose. Patient detriment index (PDI) was developed, which sets threshold (standard of practice) for comparing physician practice with their peers. Odds ratio was calculated to determine odds of a group of patients receiving dose above threshold when compared to another group. RESULTS: Median DLP among ten physicians was 1194 mGy-cm. There was a significant difference (p< 0.01) between reported DLPs doses when physicians used dose saving feature vs. when feature not used (539.8 ± 169.4 mGy-cm vs. 1269.7 ± 659.0 mGy-cm). In general, physicians who used dose saving feature had lower relative PDIs (< 1) compared to the PDIs (> 1) without the dose feature. Odds ratio estimate of 7.7 at 95% confidence level indicates that the odds of a group receiving a high dose depends on practitioner. CONCLUSION: Adjustments of practice habits, use of dose saving features or both may be needed to improve patient care for CT biopsy.
Keywords: CT fluoroscopy, radiation dose, CT dose, CT biopsy
DOI: 10.3233/XST-140427
Journal: Journal of X-Ray Science and Technology, vol. 22, no. 3, pp. 309-319, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]