Affiliations: Department of Energy Engineering, Fluid Mechanics
Section, Technical University of Denmark, Building 404, DK-2800 Lyngby,
Denmark | Dantec Measurement Technology A/S, Tonsbakken 16-18,
DK-2740 Skovlunde, Denmark
Abstract: In an assessment of PIV measurement accuracy under practical
experimental circumstances, grid-generated turbulence in its early decay (x/M =
13.6-15.2, Re_&lgr; ≈ 25) has been studied. Since a real-time
processor was used, it was practical to acquire a statistically significant
sample size of 3000 vector maps so that accurate turbulence statistics could be
calculated. Results include moments of velocity components and spatial
structures in terms of auto-correlations, turbulence scales and spectra. Data
fall within limits of standard error estimates. This study demonstrates the
need for large sample sizes, particularly for higher order statistics.