Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: UCANS IX Online Conference
Guest editors: David Baxter, Thomas Gutberlet, Koichi Kino, Yoshiaki Kiyanagi, Hiroaki Kumada, Yoshi Otake, Masato Takamura and Xuewu Wang
Article type: Research Article
Authors: Kumada, Hiroakia; * | Li, Yinuoa | Yasuoka, Kiyoshia | Naito, Fujiob | Kurihara, Toshikazub | Sugimura, Takashib | Sato, Masaharub | Matsumoto, Yoshitakaa | Matsumura, Akiraa | Sakurai, Hidekia | Sakae, Takejia
Affiliations: [a] Faculty of Medicine, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-8575, Japan | [b] High Energy Accelerator Research Organization, 1-1, Oho, Tsukuba, Ibaraki, 305-0801, Japan
Correspondence: [*] Corresponding author. E-mail: [email protected].
Abstract: The iBNCT project aims to develop “iBNCT001,” a demonstration device of the linac-based neutron irradiation facility for boron neutron capture therapy (BNCT) application. iBNCT001 generates an epithermal neutron beam by irradiating 8 MeV protons accelerated by a linac onto a beryllium target. Currently, the linac can drive an average proton current of 2.1 mA. Several experiments were performed using a water phantom to confirm the main physical characteristics of the neutron beam produced at the irradiation position. The measurement results demonstrated that the maximum thermal neutron flux achievable in the phantom volume was approximately 1.36×109 cm−2 s−1 when a normal beam collimator with a 120 mm diameter was used. This neutron beam intensity was sufficient to complete the irradiation within 30 min using the BNCT approach. In addition to normal beam collimators, extended collimators that protrude 100 mm from the wall were developed. By using an extended collimator, it is possible to prevent interference of the patient’s body with the wall when irradiating head and neck cancers. The measurement results for the extended collimator demonstrated that irradiation with the collimator could be completed within 1 h when the neutron beam is generated with an average proton current of 2.1 mA.
Keywords: Boron neutron capture therapy, LINAC, accelerator-based neutron source, phantom irradiation experiment
DOI: 10.3233/JNR-220029
Journal: Journal of Neutron Research, vol. 24, no. 3-4, pp. 347-358, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]