Article type: Research Article
Authors: Lokwani, P.a; * | Gupta, N.b | Choudhary, S.K.b | Singh, A.K.b
Affiliations: [a] Audiologist, Model Early Intervention Centre, Department of Neonatology, All India Institute of Medical Sciences, Jodhpur, India | [b] Department of Neonatology, All India Institute of Medical Sciences, Jodhpur, India
Correspondence: [*] Address for correspondence: Prateek Lokwani, Audiologist, Model Early Intervention Centre, Department of Neonatology, All India Institute of Medical Sciences, Jodhpur 342-005, India. E-mail: [email protected].
Abstract: BACKGROUND: With technological advancement, Neonatal Intensive Care Units (NICU) have become noisier than ever. Studies have shown the detrimental effects of increasing noise in NICU on growing pre-term and sick neonates. The present study aimed to survey the amount of noise in one of the NICU blocks of a government tertiary care centre and explore ways to control it when dealing with these sick babies. METHODS: A detailed noise survey was carried out, for February 2023, in one of the two blocks of NICU in a government tertiary-care centre. The noise measurements were performed using two “Sound Ear 3” noise meters. The analyses were done in Leq (equivalent continuous sound levels) A-weighted decibels (dBA). RESULTS: The extracted data analysis revealed that the NICU block was exposed to a mean Leq of 67.78 dBA noise with a maximum of 89.0 dBA. There was a significant difference between the values noted in devices at different locations and across different periods. There were certain instances (57 and 42 for two devices) when there were sudden spikes in the noise levels beyond 80 dBA. It was also seen that noise was more than 65 dBA most of the time (72% and 66% for the two devices). CONCLUSION: The noise survey carried out over one month revealed a considerable amount of noise in the NICU of a government tertiary-care centre. The study also explored ways such as environmental modification, human behavior modification, awareness programs, and neonatal-centered modifications to reduce the noise and lower its detrimental effects on the growth of neonates.
Keywords: Neonatal intensive care unit, noise awareness, noise management, noise survey
DOI: 10.3233/NPM-230031
Journal: Journal of Neonatal-Perinatal Medicine, vol. 16, no. 4, pp. 619-625, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]