Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Saha, A.K.a; * | Sardar, S.K.a | Majhi, B.b | Chatterjee, S.c
Affiliations: [a] Department of Neonatology, Institute of Post Graduate Medical Education & Research and SSKM Hospital, Kolkata, India | [b] Department of Cardiology, Bankura Sammilani Medical College and Hospital, Bankura, India | [c] Department of Pharmacology, Institute of Post Graduate Medical Education & Research and SSKM Hospital, Kolkata, India
Correspondence: [*] Address for correspondence: Dr Anindya Kumar Saha, I P G M E & R and SSKM Hospital, Department of Neonatology, 244, A J C Bose Road, Kolkata, PIN-700020, India. Tel.: +91 9830149059; E-mail: [email protected].
Abstract: BACKGROUND:In preterm infants, persistence of ductus arteriosus is an important medical condition. Functional echocardiography for patent ductus arteriosus (PDA) may guide clinical decision-making regarding treatment requirement strategies. Objectives of the study were to assess the trends of clinical and functional echocardiographic parameters with evolution of ductus arteriosus in babies≤1250 gm of birth weight and to evaluate whether there is any association of these parameters with persistence of ductus. METHODS:In this prospective observational study, recruited babies were assessed serially for clinical events and functional echocardiography. Babies were classified into three groups: without PDA, with PDA but PDA spontaneously closed (within 7 days) and persistent PDA. RESULT:We included 143 infants (Birth weight 1017±179 g, gestational age 30.8±2.7 weeks). Out of 60 babies with PDA, PDA failed to close spontaneously in first week in 32 (53.4 %) infants. PDA Doppler flow pattern on day 3 was found to be one of the most significant markers for future ductus. The highest frequency of growing pattern (37.5%) and pulsatile pattern (59.4%) was seen in persistence ductus group. PDA diameter and LA/Ao ratio were found strongly correlated with all other variables except E/A ratio. CONCLUSION:We noticed persistence of ductus in preterm infants had significant clinical and echocardiographic association. PDA doppler flow pattern on day 3 was found to be a significant marker for future behaviour of ductus. Significant correlation was found among individual functional echocardiographic parameters in babies with PDA. This would guide judicious treatment of PDA in preterm neonates.
Keywords: Functional echocardiography, patent ductus arteriosus, preterm, very low birth weight
DOI: 10.3233/NPM-210930
Journal: Journal of Neonatal-Perinatal Medicine, vol. 15, no. 3, pp. 537-544, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]