Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Khan, M.a; * | Bateman, D.b | Sahni, R.b | Leone, T.A.b
Affiliations: [a] Maimonides Medical Center, Brooklyn, NY, USA | [b] New York Presbyterian Morgan Stanley Children’s Hospital, New York, NY, USA
Correspondence: [*] Address for correspondence: Mehbeen Khan, Maimonides Medical Center, Department of Pediatrics, 4802 10th Avenue, Brooklyn, NY 11219, USA. Tel.: +718 283 8853; Fax: +718 635 8872; E-mail: [email protected].
Abstract: OBJECTIVE:To compare proportions of target range tidal volumes achieved with the self-inflating bag vs. the T-piece in resuscitation of preterm newborns at delivery. STUDY DESIGN:This randomized controlled trial was conducted at a tertiary Children’s Hospital. 20 preterm infants≤32 weeks’ gestational age with no congenital anomalies who needed positive pressure ventilation after birth were enrolled. Positive pressure ventilation was provided with the self-inflating bag or T-piece resuscitator. The primary outcome was proportion of inflations within a target range of 4–8 ml/kg. Chi-square and logistical regression analyses were performed. RESULTS:In the self-inflating bag (SIB) group 29% of inflations (117/419) and in the T-Piece (TP) group 51% of inflations (300/590) delivered expiratory tidal volume (TVe) of 4–8 ml/kg (p < 65.001). In the SIB group 60% of all inflations (254/419), and in the TP group 35% of all inflations (204/590) delivered TVe < 4 ml/kg (p < 0.001). In the SIB group 11% of all inflations (48/419), and in the TP group, 15% of all inflations (86/590) delivered TVe > 8 ml/kg (p = 0.18). The OR of having expiratory tidal volume of 4–8 ml/kg using the T-piece was 1.8 (CI 1.1–3.1), p = 0.02. CONCLUSION:Manual inflations provided by the TP deliver expiratory tidal volumes in the range of 4–8 ml/kg more consistently than SIB.
Keywords: Delivery room (DR), expiratory tidal volume (TVe), peak inspiratory pressure (PIP), positive end expiratory pressure (PEEP), positive pressure ventilation (PPV)
DOI: 10.3233/NPM-210728
Journal: Journal of Neonatal-Perinatal Medicine, vol. 16, no. 2, pp. 265-270, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]