Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Sardar, S.K.a | Saha, A.K.a; * | Majhi, B.b | Chatterjee, S.c
Affiliations: [a] Department of Neonatology, Institute of Post-Graduate Medical Education & Research and SSKM Hospital, Kolkata, India | [b] Department of Cardiology, Institute of Post-Graduate Medical Education & Research and SSKM Hospital, Kolkata, India | [c] Department of Pharmacology, Institute of Post-Graduate Medical Education & Research and SSKM Hospital, Kolkata, India
Correspondence: [*] Address for correspondence: Dr Anindya Kumar Saha, Department of Neonatology, Institute of Postgraduate Medical Education & Research, 244, A J C Bose Road, Kolkata, West Bengal, PIN-700020, India. Tel.: +91 9830149059; E-mail: [email protected].
Abstract: OBJECTIVE:To evaluate the role of functional echocardiography for prediction of patent ductus arteriosus (PDA) closure and development of adverse outcome in very low birth weight newborn. METHODS AND STUDY DESIGN:Functional echocardiography was done in 143 neonates with birth weight less than 1250 g on day 3. Nine echocardiographic parameters were analyzed for babies with PDA for prediction of spontaneous closure and development of one or more adverse outcomes (bronchopulmonary dysplasia, necrotizing enterocolitis≥stage 2 and intraventricular hemorrhage > grade 2) during hospital stay. RESULT:The mean (±SD) birthweight and gestational age of the cohort were 1017 (±17) g and 30.8 (±2.7) weeks. PDA was found in 60 (41.9%) babies on day 3 among the recruited babies. Binary logistic regression model showed strong prediction ability of early (day 3) functional echocardiography markers in predicting future spontaneous closure of PDA and development of one or more adverse clinical outcome. In multivariate analysis, abnormal flow pattern (growing or pulsatile) was found to have increased risk for persistence of PDA (adjusted OR 22.9, CI 1.97-269) in comparison to PDA with closing/bidirectional pattern. CONCLUSION:Early functional echocardiography, especially the flow pattern, is useful for prediction of PDA closure. Adverse clinical outcome prediction is possible with functional echocardiography markers when combined with gestational age and PDA closure status.
Keywords: Very low birth weight, patent ductus arteriosus, preterm, functional echocardiography
DOI: 10.3233/NPM-190229
Journal: Journal of Neonatal-Perinatal Medicine, vol. 13, no. 1, pp. 31-37, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]