Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Jangra, Manishaa | Dhull, Sanjeev Kr.a | Singh, Krishna Kantb; *
Affiliations: [a] Department of ECE, Guru Jambheshwar University of Science & Technology, Hisar, Haryana, India | [b] Department of Electronics and Communication Engineering, KIET Group of Institutions, Ghaziabad, India
Correspondence: [*] Corresponding author. Krishna Kant Singh, Department of Electronics and Communication Engineering, KIET Group of Institutions, Ghaziabad, India. E-mail: [email protected].
Abstract: In this paper, the authors propose an improved convolutional neural network for automatic arrhythmia classification using Electro-Cardio-Gram (ECG) signal. It is essential to periodically monitor the heart beat arrhythmia to reduce the risk of death due to cardiovascular disease (CVD). The Visual Geometry Group network (VGGNet) is being widely used in computer vision problems. However, the same network cannot be used for classification of ECG beats as ECG signal is different from image signal in terms of dimensionality and inherent features. Thus, the authors investigated the effect of decreasing depth and width of a convolutional neural network in context of cardiac arrhythmia classification. In this paper, six configurations differing in depth and width are evaluated using benchmark MIT-BIH database. A deep network having thirteen convolution layers but with a smaller number of filters (reduced width) showed outstanding performance for the given problem. Based on the findings, the work is further extended to propose an improved convolutional neural network named as modified VGGNet (mVGGNet) for the task of ECG arrhythmia classification into four classes which are normal (N), ventricular ectopic beat (VEB), supraventricular ectopic beat (SVEB) and fusion beat (F). The hyper-parameters of the proposed architecture were optimized using sequential model based global optimization (SMBO) algorithm. The proposed architecture is evaluated using subjected-oriented patient-independent evaluation protocol. The performance is evaluated using five-fold cross-validation. The proposed mVGGNet achieved 98.79% and 99.16% accuracy for ventricular ectopic beats (VEB) and supraventricular ectopic beats (SVEB) classification respectively. The proposed method resulted in higher specificity and precision as compared to other state-of-the-art algorithms. Thus, it can be effectively used for ECG arrhythmia classification.
Keywords: Deep learning, ECG, arrhythmia, VGGNet, convolutional neural network
DOI: 10.3233/JIFS-191135
Journal: Journal of Intelligent & Fuzzy Systems, vol. 38, no. 3, pp. 3151-3165, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]