Affiliations: College of Paper & Environmental Engineering,
South ChianUniversity of Technology, Guangzhou, 510640.
E-mail:[email protected]; [email protected]
Abstract: The effects of the colorimetric buffer solutions were investigated
while the two colorimetric reactions of A1-ferron complex and Fe-ferron complex
occurred individually, and the effects of the testing wavelength and the pH of
the solutions were also investigated. A timed complexation colorimetric
analysis method of A1-Fe-ferron in view of the total concentration of {A1+Fe}
was then established to determine the species distribution of polymeric Al-Fe.
The testing wavelength was recommended at 362 nm and the testing pH value was
5. Based on the ratios of n_Al/n_Fe, the standard adsorption curves of the
polymeric Al-Fe solutions were derived from the experimental results.
Furthermore, the solutions composition were various in both the molar
n_Al/n_Fe ratios, i.e. 0/0, 5/5, 9/1 and 0/10, and the concentrations
associated with the total [Al + Fe] that ranged from 10^-^5 to 10^-^4
mol/L.
Keywords: polymeric aluminum-ferrum, Al-Fe-ferron, timed complexation colorimetric analysis method, species distribution