Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhang, Juna | Chen, Zongrena | Wu, Weimeia; * | Shao, Liuyangb | Deng, Kaihuanb | Gao, Shixiongb
Affiliations: [a] Computer Engineering Technical College (Artificial Intelligence College), Guangdong Polytechnic of Science and Technology, Zhuhai, Guangdong, China | [b] School of Control and Computer Engineering, North China Electric Power University, Beijing, China
Correspondence: [*] Corresponding author: Weimei Wu, Computer Engineering Technical College (Artificial Intelligence College), Guangdong Polytechnic of Science and Technology, Zhuhai, Guangdong 519090, China. E-mail: [email protected].
Abstract: Fault detection for photovoltaic power generation system is a challenging problem in condition monitoring and troubleshooting, which aims to maintain the safe operation of equipment and improve the benefit of photovoltaic industry. Aiming at the problems of frequent failures of photovoltaic power generation system, large amount of operating data and difficult to obtain fault samples, we propose an unsupervised fault detection approach for photovoltaic power generation system via bidirectional long/short memory deep auto-encoder which combines the auto-encoder in deep learning with the Bi-directional Long Short-Term Memory (BiLSTM). Specifically, We first take the statistical feature enhanced as the input of an auto-encoder based on BiLSTM. Then, we build a simulation model of Grid-connected PV system. Finally, we use the operation results under normal conditions to train the fault detection model to obtain the reconstruction error and determine the fault detection threshold, so as to judge the anomalies of the photovoltaic power generation system. We simulate the shadow occlusion fault and verify the effectiveness of the proposed method, and the fault detection accuracy of 0.95 is achieved. Compare with other models, the results show that it could set up better dependence on multi-dimensional data in time sequences, effectively testing solar panel failures and solving insufficient data labels problems.
Keywords: Fault detection, deep learning, photovoltaic power generation system, deep auto-encoder, bidirectional long/short memory
DOI: 10.3233/JCM-237070
Journal: Journal of Computational Methods in Sciences and Engineering, vol. 24, no. 2, pp. 849-861, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]