Affiliations: [a] School of Information Engineering, Nanchang University, Nanchang, Jiangxi, China | [b] Beijing Key Laboratory of Demand Side Multi-Energy Carriers Optimization and Interaction Technique (China Electric Power Research Institute), Beijing, China | [c] State Grid Ningxia Electric Power Co., Ltd., Yinchuan, Ningxia, China
Correspondence: [*] Corresponding authors: Bihong Tang and Xuan Wen, School of Information Engineering, Nanchang University, Nanchang, Jiangxi 330031, China. E-mail: [email protected] and [email protected].
Abstract: With the large-scale grid integration of new energy sources, the power relationship between source and demand side is becoming more and more complex, the flexibility requirements of the distribution network are increasing, and new requirements for system safety and reliability are put forward, and it can’t meet the peak regulating requirements of grid by relying solely on source side to cope with variable loads. In view of this, to make the grid operation flexibility improved by using an adjustable load capacity, the study first constructs a load classifying method on the foundation of fuzzy style K-plane clustering method to understand the interaction information of the load devices. Then the adjustable value of the load is analyzed from the demand response and standby perspectives, respectively, and an improved dynamic time-bending-based source-load similarity inscription method is proposed, which aims to unify the multiple load information obtained by clustering. The proposed clustering algorithm takes the highest value of 0.096 for the Davies-Bouldin index index, which is 0.012 and 0.014 higher than the K-plane clustering algorithm and the K-means algorithm, respectively. In addition, the load demand response regulation with the improved dynamic time bending method has a higher capacity for new energy consumption than the variance method, with a difference of 2.0 kW. This indicates that using load regulation to consume new energy to exploit the load curve will stimulate the active participation of customer-side load in maintaining power balance between the electricity consumption side and the demand side, and form an interest community between power supplying and demanding sides.
Keywords: Renewable energy, demand side, clustering, median dynamic time warping, standby capacity
DOI: 10.3233/JCM-226944
Journal: Journal of Computational Methods in Sciences and Engineering, vol. 23, no. 5, pp. 2275-2289, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]