Abstract: In order to explore the flexural performance of the two-span simply supported to continuous T-beam using UHPC material instead of prestressed tendons in the negative bending moment zone and the effect of the UHPC material connection length on the bearing capacity of the test beam, the flexural tests of three beams with different UHPC connection lengths were carried out. The results show that by using UHPC material instead of prestressed tendons to make continuous beams in the negative bending moment region, the tensile properties and high elastic modulus characteristics of UHPC material can be better exerted. The three test beams were all resistant to bending failure, and the cracks were distributed in the two positive and negative bending moment sections. Increasing the connection length of the UHPC material will increase the distribution range of cracks and the number of cracks in the positive moment section and the cracking load in the negative moment section. The ductility was reduced. When the connection length was increased from 300 mm to 2200 mm and 2300 mm, respectively, the bearing capacity of the test beam was increased by 4% and 6%, respectively, and the mid-span ultimate displacement was reduced by 7% and 12%, respectively. The flexural performance of the test beam was improved.
Keywords: Continuous beam, UHPC, positive moment, concrete, experimental study
DOI: 10.3233/JCM-226821
Journal: Journal of Computational Methods in Sciences and Engineering, vol. 23, no. 4, pp. 1765-1776, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]