Abstract: In order to reduce the influence of noise on the stability of cyclic signal transmission and improve the effect of signal control, a method to control the stability of cyclic signal transmission of high-power driving circuit is proposed. The main components of the driving circuit and the characteristics of its cyclic signal are analyzed. According to the analysis results, a cyclic signal transmission interference detection module is designed, and the source interference detection is realized by using this module; Considering the electromagnetic influence of the circulating signal and the power part, the optocoupler isolation method is used to isolate the circulating signal; On the basis of detecting and isolating the transmission interference of circulating signal, the primary pulse width modulation signal and the secondary fault feedback signal are modulated by a single pulse transformer to realize the bidirectional transmission design of circulating signal; The internal optimization design of the high-power drive circuit is carried out, the error correction of the signal transmission stability control is carried out by using the linearized small interference error compensation method, and the empirical mode decomposition method is applied to the cyclic signal analysis of the high-power drive circuit to solve the cross term interference problem in the cyclic signal analysis. Finally, the stability control of cyclic signal transmission is realized by using double quasi PR controller. The experimental results show that the signal transmission time of this method is short, the minimum value is less than 0.5 s, the signal transmission deviation is only 0.22, the transmission rate is high, the signal transmission deviation is small, and the signal waveform is stable, which fully shows that its control effect is good.
Keywords: Monopulse transformer, optocoupler isolation method, pulse width modulated signal, secondary fault feedback signal, high power drive circuit, interference detection
DOI: 10.3233/JCM226429
Journal: Journal of Computational Methods in Sciences and Engineering, vol. 22, no. 6, pp. 1903-1916, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]