Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Freedman, M.R.; * | Gaitanis, A. | Spyrou, N.M.
Affiliations: Department of Physics, School of Electronics and Physical Sciences, University of Surrey, Guidlford, Surrey, GU2 7XH, UK
Correspondence: [*] Corresponding author. E-mail: [email protected].
Abstract: Electrical Impedance Epigastrography (EIE) is a non-invasive method that allows the assessment of gastric emptying rates without using ionizing radiation. This method works by applying an alternating current with a frequency of 32 kHz, which can be varied by the operator from 1 to 4 mA, through electrodes over the epigastric region, and measuring the potential difference between them. The post acquisition analysis relies on the Short-Time Fourier Transform (STFT) to extract the gastric motility component of the signal (centre frequency of 0.05 Hz with a bandwidth of 0.02 Hz). Motion artifacts that occur during the test have been found to produce positive and negative spikes. Software was produced to model the EIE signals and apply simulated motion artifacts of known amplitude at specific points in the signal. The signals were labelled pseudo EIE signals. Due to the large frequency range of a delta function, the spikes produced false positives in the frequency domain, suggesting the presence of gastric contractility when there was none, or exaggerating the magnitude of real events in both real and pseudo EIE signals. A motion artifact rejection algorithm (MARA) was developed for removing the artifacts in the time domain, before processing by the STFT. The efficacy of the algorithm was tested on the pseudo EIE signals by comparing the power density calculated by the STFT before and after the simulation of artifacts and after the application of the algorithm.
Keywords: Electrical impedance epigastrography (EIE), signal processing, MARA, motion artifacts, Short-time fourier transform (STFT), continuous wavelet transform (CWT)
DOI: 10.3233/JCM-2005-5102
Journal: Journal of Computational Methods in Sciences and Engineering, vol. 5, no. 1, pp. 17-26, 2005
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]