Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Subtitle:
Article type: Research Article
Authors: Staniszewski, Michaƚa; * | Urbanik, Czesƚawb | Mastalerz, Andrzejb | Lutosƚawska, Grażynac | Iwańska, Dagmarab | Madej, Annab | Karczewska, Magdalenab | Tkaczyk, Joannac
Affiliations: [a] Department of Water Sports and Winter Sports, Faculty of Physical Education, Józef Piƚsudski University of Physical Education, Warsaw, Poland | [b] Department of Biomechanics, Faculty of Physical Education, Józef Piƚsudski University of Physical Education, Warsaw, Poland | [c] Department of Biochemistry and Biology, Faculty of Physical Education, Józef Piƚsudski University of Physical Education, Warsaw, Poland
Correspondence: [*] Corresponding author: Michaƚ Staniszewski, Faculty of Physical Education, Józef Piƚsudski University of Physical Education, 34 Marymoncka Str; P.O. Box 55, 00-968 Warsaw 45, Poland. Tel.: +48 501 08 09 43; Fax: +48 22 835 00 67; E-mail:[email protected]
Abstract: BACKGROUND: Muscle strength depends among other factors on its length, i.e., the angular position of the joint it spans. However, these relationship is often neglected in the construction of training machines. OBJECTIVE: The aim of this study was to verify the effectiveness of a variable-cam during strength training. METHODS: Thirty-two men divided into two groups participated in an 8-week intensive strength training of elbow flexors. One group (C) trained on a machine with a cam developed in the shape corresponding to the strength change characteristics of flexor muscles as a function of the angular position in the elbow joint. The second group (D) trained on a machine with a disc plate. The effects of the training were evaluated on the basis of changes in the value of PT measured under isokinetic conditions, anthropometric parameters, and CK activity. RESULTS: After the end of the training, a significant increase in the values of the PT and anthropometric parameters were observed only in group C. Weekly changes of CK activity appeared only in the group exercising with a cam, while in the group exercising on the machine with a disc plate, the two-day rest turned out to be too short for the elimination of the CK molecules from the blood to occur. CONCLUSIONS: Strength training using a machine with a muscle-specific adjusted cam is especially effective in the case of the elbow flexors.
Keywords: Intensive training, biceps brachii, isokinetic muscle strength, CK activity
DOI: 10.3233/IES-150576
Journal: Isokinetics and Exercise Science, vol. 23, no. 3, pp. 161-168, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]