Article type: Research Article
Authors: Mattacola, Carl G.a; *; ** | Perrin, David H.a; ***
Affiliations: [a] University of Virginia
Note: [*] Doctoral Student in Sports Medicine, University of Virginia, Charlottesville, VA 22901.
Note: [**] Address reprint requests to Carl G. Mattacola, Hampden-Sydney College, Hampden-Sydney , VA 23943.
Note: [***] Associate Professor and Director, Sports Medicine/Athletic Training Research Laboratory and Graduate Athletic Training Education, University of Virginia, Charlottesville, VA 22901.
Abstract: Cold (cryotherapy) is commonly applied to an athlete immediately before and/or after sports participation. The purpose of this study was to determine the effect of cold water submersion (CWS) on isokinetic strength of the plantar flexor muscle group. Eleven women and five men (mean age 22.1 years, height 170.8 cm, weight 64.5 kg) with no history of ankle joint pathology were tested for peak torque, average power, and total work of the dominant foot at 60 deg/sec with a Cybex II isokinetic dynamometer. Before isokinetic testing subjects were randomly assigned to either CWS or an inactive rest period (RP). Subjects returned 1 week later to receive the opposite treatment and undergo isokinetic testing. The CWS consisted of placing the leg in a 15° C tub of water for 20 minutes. The RP consisted of remaining seated for a 20-minute period. Paired t tests were computed to determine if any differences existed in peak torque, average power, and total work between the CWS and RP conditions. Results indicated concentric isokinetic strength values were lower after CWS for peak torque, average power and total work of the plantar flexor muscle group. These findings indicate that concentric isokinetic torque, power, and work of the plantar flexor muscle group are reduced immediately after CWS. Further research should be undertaken to determine the length of time isokinetic output is reduced before returning to normal responses after CWS is present.
Keywords: Cold water (cryotherapy), plantar flexors, isokinetic concentric assessment
DOI: 10.3233/IES-1993-3305
Journal: Isokinetics and Exercise Science, vol. 3, no. 3, pp. 152-154, 1993
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]