Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Byl, Nancy N.a; *; ** | Wells, Lauriea; *** | Grady, Deboraha; **** | Friedlander, Annea; ***** | Sadowsky, Stevea; ******
Affiliations: [a] University of California, San Francisco
Note: [*] UCSF Graduate Program in Physical Therapy, School of Medicine, Box 0376, 374 Pamassus, San Francisco, CA 94122.
Note: [**] Address reprint requests to Nancy Byl, PhD, PT, Director, UCSF Graduate Program in Physical Therapy, Assistant Professor, Box 0376, 374 Pamassus Ave., San Francisco, CA 94122.
Note: [***] Department of Veterans Affairs Medical Center, Department of Physical Therapy, Room 117, 4150 Clement St., San Francisco, CA 94121.
Note: [****] Epidemiology and Biostatistics, Division of General Medicine, School of Medicine, Box 0866,74 New Montgomery #600, San Francisco, CA 94104.
Note: [*****] Department of Radiology, Box 0628, U368, School of Medicine, San Francisco, CA 94121.
Note: [******] UCSF Graduate Program in Physical Therapy, School of Medicine, Box 0376, 374 Pamassus, San Francisco, CA 94122.
Abstract: Normative data are needed to permit physical therapists to determine if patient measurements of strength are within normal limits. However, to generate normative data, it is essential to evaluate large numbers of subjects. This is only possible with collaboration to pool measurements across different sites with different examiners. This study evaluated the consistency of repeated isokinetic knee flexion and extension measurements with the same subjects tested on the Cybex 340 Extremity Unit with two different examiners at two different sites following the same protocol and then different protocols. The t test was used to determine if the mean difference scores significantly varied from zero (p = .05). Within the same site, following the same protocol, there were no significant differences in measurement by the two examiners for peak torque (at 90, 120, or 180 deg/sec), work in flexion (120 deg/sec) or endurance (120 deg/sec), but there was a significant difference in work extension. By site, there were no significant differences in repeated measurements for peak torque, work, or endurance (120 deg/sec). There were significant differences in peak torque flexion when different protocols were used, even when the same examiner was testing at the same site. The coefficients of variation for the repeated measurements varied from 4.5% to 13.6%. The results from this study suggest that physical therapists from different sites could collaborate to pool data for developing norms for isokinetic knee flexion and extension torque as long as the same test protocol was followed. However, the large variation in retest measurements and the coefficient of variation suggest that when a therapist wants to determine if a patient has made a significant gain in strength, the remeasurement should be taken by the same examiner at the same site. More research is needed to determine if the consistency of isokinetic torque testing with different examiners and different sites is equally high for other muscle groups and with other types of isokinetic dynamometers.
Keywords: Reliability, isokinetic testing, knee, Cybex 340
DOI: 10.3233/IES-1991-1302
Journal: Isokinetics and Exercise Science, vol. 1, no. 3, pp. 122-130, 1991
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]