Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Alt, Tobiasa | Knicker, Axel J.a | Strüder, Heiko K.a
Affiliations: [a] Institute of Movement and Neuroscience, German Sport University, Cologne, Germany
Note: [] Corresponding author: Tobias Alt, Institute of Movement and Neuroscience, German Sport University, Am Sportpark Müngersdorf 6, 50933 Cologne, Germany. Tel.: +49 221 4982 3322; Fax: +49 221 4973 454; E-mail: [email protected]
Abstract: BACKGROUND: Although the reliability of isokinetic strength tests of knee flexors (flex) and extensors (ext) has been examined several times, statistical evidence about the influence of internal and external factors is missing. OBJECTIVE: This study aims to examine the impact of familiarisation, muscle group, contraction mode, angular velocity and test parameters on the reproducibility of findings derived from an isokinetic dynamometer (IsoMed 2000). METHODS: Thirty-three male subjects (mean age: 22.3 years) with no prior experience of isokinetic exercise participated in three identical test sessions (T1, T2, T3), each separated by 48–72 h. Peak moment (PM), angle of peak moment (APM) and contractional work (CW) were determined unilaterally (left and right) during maximum concentric (con) and eccentric (ecc) knee flexion (abdominal position) and extension (supine position) at 30, 90 and 150°/s, respectively. An ANOVA with repeated measures confirmed systematic bias. Reproducibility of consecutive tests (T1–T2, T2–T3) was assessed by calculating the intra-class correlation coefficient (ICC 2,1) (relative reliability) as well as the standard error of measurement (SEM) (absolute reliability). ICC values were averaged according to respective factors (Fisher's z-transformation) and tested for significant differences by Steiger's formulas. RESULTS: PM and CW demonstrated a high absolute reliability (SEM: 4.7–10.5%). Relative reproducibility varied considerably (p⩽ 0.05) between muscles (ecc flex > ecc ext), contraction modes (con ext > ecc ext) and test parameters (PM=CW > APM), but did not depend on angular velocity (30=90=150°/s). Due to familiarisation the reliability of PM obtained from eccentric knee extensions significantly increased (T2–T3 > T1–T2). CONCLUSIONS: These results improve the development and execution of reliable isokinetic strength testing protocols for unilateral knee flexion and extension together with the interpretation of different test parameters.
Keywords: Reproducibility, intra-class correlation coefficient, standard error of measurement, maximum strength testing, familiarisation, IsoMed 2000
DOI: 10.3233/IES-140555
Journal: Isokinetics and Exercise Science, vol. 22, no. 4, pp. 333-342, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]