Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: McMeeken, Joan M.a | Story, Ian H.a | Smith, Jennib | Ken, Petera
Affiliations: [a] School of Physiotherapy, The University of Melbourne, Parkville 3052, Australia | [b] Physiotherapy Department, Royal Melbourne Hospital, Parkville 3052, Australia
Note: [] Corresponding author: Joan McMeeken, School of Physiotherapy, The University of Melbourne, Parkville 3052, Australia. Tel.: +61 3 9344 4171; Fax: +61 3 9344 4188; E-mal: [email protected]
Abstract: Reliability of measurement of maximum isokinetic muscle performance in subjects with rheumatoid arthritis has not been reported for the KinCom dynamometer. The aim in this study was to estimate intra and inter-session reliability in knee extensor and flexor muscles. Concentric peak torque (Nm) of knee extension and flexion at 60o.s-1 and 120o.s-1 was measured in 18 subjects (49.7 +/- 5.3 (29-76) years) with rheumatoid arthritis using a standardised protocol. Intra-session reliability (ICC 3,1) assessed in six subjects was found to be high in extensor (0.99) and flexor muscles (0.99). Comparison between left and right knees showed no statistically significant differences. Inter-session reliability (ICC 2,3) assessed over a six-week interval was also high for extensors (60o.s-1 = 0.97, 120o.s-1 = 0.97) and flexors (60o.s-1= 0.94, 120 o.s-1= 0.97). These findings indicate that when using a single rater, inter and intra-session reliability of knee muscle peak isokinetic concentric torque measurement are acceptable. The time interval between test sessions of six weeks reflects the clinical environment. Therefore this protocol provides a useful test for evaluation of therapeutic interventions directed at the knee.
Keywords: rheumatoid arthritis, reliability, knee muscles
DOI: 10.3233/IES-1998-0019
Journal: Isokinetics and Exercise Science, vol. 7, no. 2, pp. 67-73, 1998
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]