Article type: Research Article
Authors: Rizzi, Maria; * | D'Aloia, Matteo | Castagnolo, Beniamino
Affiliations: Dipartimento di Elettrotecnica ed Elettronica, Politecnico di Bari, Bari, Italy
Correspondence: [*] Corresponding author: Prof. Maria Rizzi, Dipartimento di Elettrotecnica ed Elettronica, Politecnico di Bari, via E. Orabona, 4, 70125 Bari, Italy. Fax: +39 0805963410; E-mail: [email protected].
Abstract: Over recent years breast cancer prevention campaigns have resulted in widespread screening. Until now, mammography has been one of the most reliable methods for the early detection of this disease. The high correlation between the appearance of microcalcification clusters and the presence of cancer shows that Computer Aided Detection systems of microcalcifications are extremely useful and helpful in an early detection of breast cancer. Several techniques can be adopted to accomplish this task. In this paper an efficient tool for a fully automatic microcalcification cluster detection/localization is presented. Adopting this procedure, all suspect microcalcifications are preserved and background noise is reduced by thresholding mammograms through a wavelet filter, according to image statistical parameters (i.e. mean gray level pixel value and standard deviation). Moreover, in order to localize singularity points, the reconstructed image is decomposed adopting another wavelet and each decomposition level is processed using a hard threshold technique. To reduce false positive detections in microcalcification recognition, the results obtained in each level are combined with a suitable procedure. The Mammographic Image Analysis Society database is used to test the procedure. The performance obtained highlights the validity of the method; indeed, the evaluated sensitivity parameter (true positive rate) is about 98% at an average rate of 1 false positive per image.
Keywords: Microcalcifications, computer aided detection, mammography, wavelet transforms
DOI: 10.3233/ICA-2009-0306
Journal: Integrated Computer-Aided Engineering, vol. 16, no. 2, pp. 91-103, 2009
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]