Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Abazari, Reza1; * | Lakestani, Mehrdad2
Affiliations: [1] Department of Mathematics, Faculty of Sciences, University of Mohaghegh Ardabili, Ardabil, Iran | [2] Department of Applied Mathematics, Faculty of Mathematical Sciences, University of Tabriz, Tabriz, Iran. E-mail: [email protected]
Correspondence: [*] Corresponding author.
Abstract: Medical Ultrasound is a diagnostic imaging technique based on the application of ultrasound in various branches of medical sciences. It can facilitate the observation of structures of internal body, such as tendons, muscles, vessels and internal organs such as male and female reproductive system. However, these images usually degrade by a special kind of multiplicative noise called speckle. The main effects of speckle noise in the ultrasound images appear in the edges and fine details which lead to reduce their resolution and consequently make difficulties in medical diagnosing. Therefore, reducing of speckle noise seriously plays an important role in image diagnosing. Among the various methods that have been proposed to reduce the speckle noise, there exists a class of approaches that firstly convert multiplicative speckle noise into additive noise via log-transform and secondly perform the despeckling process via a directional filter. Usually, the additive noises are mutually uncorrelated and obey a Gaussian distribution. On the other hand, non-subsampled shearlet transform (NSST), as a multi scale method, is one of the effective methods in image processing, specially, denoising. Since NSST is shift invariant, it diminishes the effect of pseudo-Gibbs phenomena in the denoising. In this paper, we describe a simple image despeckling algorithm which combines the log-transform as a pre-processing step with the non-subsampled shearlet transform for strong numerical and visual performance on a broad class of images. To illustrate the efficiency of the proposed approach, it is applied on a sample image and two real ultrasound images. Numerical results illustrate that the proposed approach can obtain better performance in term of peak signal to noise ratio (PSNR) and structural similarity (SSIM) index rather than existing state-of-the-art methods.
Keywords: ultrasound image, discrete shearlet transform, non-subsampling, log-transform, speckle noise
Journal: Informatica, vol. 30, no. 1, pp. 1-19, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]