Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Vörös, Esztera | Deres, Lászlób | Halmosi, Róbertb | Várady, Edita | Tóth, Kálmánb | Battyáni, Istvána; *
Affiliations: [a] Department of Radiology, University of Pecs Medical School, Pecs, Hungary | [b] 1st Department of Internal Medicine, University of Pecs Medical School, Pecs, Hungary
Correspondence: [*] Corresponding author: Istvan Battyani, MD., Ph.D., Department of Radiology, University of Pecs Medical School, 12 Szigeti Street, Pecs, H-7624, Hungary, Tel.: +36 302383906/309279146; Fax: +3672549320; E-mail: [email protected].
Abstract: BACKGROUND AND PURPOSE: Iodinated contrast media (Xenetix®, Ultravist®, Omnipaque®, Visipaque® and Iomeron®) used for computed tomography (CT) may decrease fibrinolysis by recombinant tissue plasminogen activator (rt-PA). We hypothesized that receiving iodinated contrast media before rt-PA may impair thrombolysis as measured by a new model system. METHODS: Whole blood from Wistar Kyoto rats (n = 10) was obtained and allowed to form blood clots. Thrombolysis was performed by placing individually the prepared clots into 15 mL tubes and adding 5 mL saline buffer, 100μg rt-PA and a different contrast media; adjusting the quantity of iodine to either 30 mg or 60 mg. The thrombolytic efficacy was quantified by measuring the optical density (OD415) of the supernatant at different time points, namely at 0, 30, 60, and 90 min. RESULTS: There was a significant decrease in clot lysis efficiency observed in presence of iodine containing contrast media comparing to positive control group. Moreover, when the quantity of iodine was increased from 30 mg to 60 mg; the dissolution rate downturned with additional ∼50%. CONCLUSION: In conclusion, our study suggests that high dose of iodine potentially could negatively affect the efficiency of the thrombolytic therapy performed by rt-PA.
Keywords: Contrast media, thrombus, rt-PA, thrombolytic therapy, computed tomography
DOI: 10.3233/CH-170261
Journal: Clinical Hemorheology and Microcirculation, vol. 66, no. 2, pp. 167-174, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]