Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Targeted Imaging of Neoplasia in the Digestive Tract
Guest editors: Thomas D. Wang
Article type: Research Article
Authors: Muguruma, Naoki; * | Ito, Susumu
Affiliations: Department of Digestive and Cardiovascular Medicine, The University of Tokushima Graduate School, Tokushima City, Japan
Correspondence: [*] Corresponding author: Naoki Muguruma, MD, PhD, Department of Digestive and Cardiovascular Medicine, The University of Tokushima Graduate School, Kuramoto-cho 3-18-15, Tokushima City, Tokushima 770-8503, Japan. Tel.: +81 88 633 7124; Fax: +81 88 633 9235; E-mail: [email protected].
Abstract: The goal of our study was to develop a method for molecular imaging of the gastrointestinal tract using an infrared fluorescence endoscope (IRFE) and antibodies labeled with an indocyanine green (ICG) derivative to detect cancerous tissue. The IRFE comprised an infrared endoscope equipped with excitation (710–790 nm) and barrier (810–920 nm) filters. We developed ICG-N-hydroxysulfosuccinimide ester (ICG-sulfo-OSu) and 3-ICG-acyl-1,3-thiazolidine-2-thione (ICG-ATT) as infrared fluorescent-labeling reagents, and anti-human carcinoembryonic antigen (CEA) antibody and MUC1 antibody were labeled with the ICG-derivatives. Freshly resected specimens of gastric cancer were observed by IRFE after reaction with ICG-derivative-labeled antibodies. Positive fluorescence was observed at the tumor location by IRFE, and the immunofluorescent images correlated well with the tumor sites. The immunofluorescence studies suggested that the intensity of the infrared fluorescence of the ICG-ATT-labeled MUC1 antibody is stronger than the ICG-sulfo-OSu-labeled MUC1 antibody. We concluded that specific antibodies for gastrointestinal cancer labeled with an ICG-derivative accompanied by a reinforcing agent and an optimal electronic device can generate a strong enough fluorescent signal to visualize cancer proteins.
Keywords: Infrared, molecular imaging, endoscope, fluorescence, antibody
DOI: 10.3233/CBM-2008-4604
Journal: Cancer Biomarkers, vol. 4, no. 6, pp. 321-328, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]