Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Natalicchio, Cortneya | Al-Khateeb, Hadib | Chajes, Michael J.c | Wu, Zheng Y.d | Shenton III, Harry W.e; *
Affiliations: [a] Rummel, Kleppar, & Kahl, Baltimore, MD, USA | [b] Jacobs Engineering, New York, NY, USA | [c] Department of Civil and Environmental Engineering, University of Delaware, Newark, DE, USA | [d] Bentley Fellow, Bentley Systems, Incorporated, Watertown, CT, USA | [e] Department of Civil and Environmental Engineering, University of Delaware, Newark, DE, USA
Correspondence: [*] Corresponding author: Harry W. Shenton III, Department of Civil and Env. Engineering, University of Delaware, Newark, DE 19716, USA. Tel.: +1 302 831 2447; Fax: +1 302 831 3640; E-mail: [email protected].
Abstract: Structural Health Monitoring (SHM) systems, in combination with controlled load tests, can provide valuable data for calibrating high fidelity bridge models, which can then be used for evaluating the long-term performance of the bridge, improved load ratings, and permit vehicle evaluation. The objective of this research was to calibrate a 3D model of the Indian River Inlet (IRIB) cable-stayed bridge, using strains recorded by the bridge SHM system during a controlled load test. The bridge was modeled in STAAD-Pro and calibrated using a pre-commercialized software platform that uses a Generic Algorithm to minimize the error between the measured and predicted strains. The calibration parameters were the elastic modulus of groups of the main longitudinal edge girder/deck elements, which once calibrated, could be related to the measured concrete strength of the members. Four different models were investigated, using 6, 10, 14, and 18 parameter element groups of the edge girder members. Of the different models, the 14 and 18 parameter models yielded the best results. The “design” model yielded errors as high as 42% when compared to the measured strains; the error was less than 10% for the majority of measurements for the 14-parameter model. Including the effect of the traffic barriers in the model, the weighted average concrete strength of the calibrated model was within 4% of the measured weighted strength. The calibration was shown to be insensitive to measurement noise and was validated using several unique single and multi-vehicle load cases that were heavier and more offset from the centerline of the bridge. The calibration procedure was able to capture the variability in flexural stiffness of the edge girders due to the variability of the concrete, resulting in significantly better agreement between the live load measured strains and the model predicted strains.
Keywords: Calibration, cable-stayed bridge, concrete, concrete strength, strain, load test, structural health monitoring, system identification
DOI: 10.3233/BRS-220195
Journal: Bridge Structures, vol. 18, no. 1-2, pp. 45-62, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]