Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Jendrzejewski, J. | Hills, J. | Hopwood, T.
Affiliations: Applied Technical Services, Louisville, KY, USA | Applied Technical Service, Marietta, GA, USA | Kentucky Transportation Center, University of Kentucky, Lexington, KY, USA
Note: [] Corresponding author. J. Jendrzejewski, Applied Technical Services, Louisville, KY, USA. E-mail: [email protected]
Abstract: In September 2011, the I-64 Sherman Minton Bridge over the Ohio River between New Albany, IN and Louisville, KY was closed due to the detection of cracks in fracture-critical tie chord members. The bridge remained closed for over five months while non destructive testing and repairs were performed. Metallurgical evaluations were conducted by Applied Technical Services, Inc. (ATS) on 21 cores extracted from fracture critical members of the bridge. The cores were reported to contain rejectable indications as identified by visual inspection (VT), magnetic particle inspection (MT), ultrasonic testing (UT) and/or radiographic testing (RT). The purpose of this investigation was to determine the nature and cause of the flaws and if there was any evidence of active propagating cracks. Of the 21 cores examined, 11 contained surface flaws within the vertical butt welds or heat-affected zones. One core contained a major subsurface planar discontinuity. Five cores contained minor subsurface indications. The base metal properties were consistent with high yield strength, quenched-and-tempered low alloy steel, i.e. “T1®”/ASTM A514. The weld metal properties were also consistent with low alloy steel. All flaws and other weld discontinuities observed both at and below the surface of the web members were associated with the original tie chord welds or subsequent early weld repairs. These flaws were formed during or shortly after welding while in the fabrication shop. Fracture mechanics calculations determined that at a critical flaw size, temperatures below 30° F (−1.1°C) could possibly result in failure of the bridge. Metallurgical analysis of the flaws revealed no evidence of active crack growth due to fatigue, corrosion fatigue or stress corrosion. The flaw surfaces exhibited intergranular separation along with mixed mode brittle and ductile features characteristic of hydrogen-induced cracking. The fracture critical members of the tie chords box girders were reinforced by bolted steel plates and the bridge placed back in service in February, 2012.
Keywords: Metallurgical evaluation, visual inspection, magnetic particle inspection, radiographic testing, critical flaw size
DOI: 10.3233/BRS-140076
Journal: Bridge Structures, vol. 10, no. 2-3, pp. 87-103, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]