Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kulkarni, Mayuresha | Dendere, Ronalda | Nicolls, Fredb | Douglas, Tania S.a; *
Affiliations: [a] Division of Biomedical Engineering, University of Cape Town, Cape Town, South Africa | [b] Department of Electrical Engineering, University of Cape Town, Cape Town, South Africa
Correspondence: [*] Corresponding author: Tania Douglas, Division of Biomedical Engineering, Faculty of Health Sciences, University of Cape Town, Observatory 7935, Cape Town, South Africa. Tel.: +27 021 406 6235; Fax: +27 021 448 7226; E-mail: [email protected].
Abstract: BACKGROUND:Digital breast tomosynthesis (DBT) reconstructs planar slices of the breast based on two-dimensional angular projections. Early studies and clinical trials show that DBT is an improvement over full field digital mammography (FFDM) because it provides the radiologist with better image quality and more information. OBJECTIVE:This paper presents a simulation system to model the performance of a slot-scanning FFDM and DBT system. METHODS:A tissue-equivalent three dimensional (3D) breast phantom was constructed, validated for slot-scanning digital mammography and used in simulating digital breast tomosynthesis. The simulation system was validated by comparing images acquired with a slot-scanning mammography machine with simulated phantom images, using the edge-test method and image quality metrics modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE). Different two-dimensional (2D) projections of the 3D phantom were simulated and the phantom was reconstructed using filtered backprojection. RESULTS:Image quality metrics showed equivalence between simulated and real images. CONCLUSIONS:The simulation tool is suitable for slot-scanning FFDM and DBT and may be used for the design and comparison of mammography systems.
Keywords: Monte-Carlo, slot-scanning, simulation, PENELOPE, DBT, FFDM.
DOI: 10.3233/XST-160543
Journal: Journal of X-Ray Science and Technology, vol. 24, no. 2, pp. 191-206, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]