Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kerr, Lawrencea; * | Wilkerson, Sheliaa; ** | Bandy, William D.a; ***; **** | Ishee, Jimmya; *****
Affiliations: [a] University of Central Arkansas, Conway, AR
Note: [*] Students in the Masters program, Department of Physical Therapy, University of Central Arkansas, Conway, AR.
Note: [**] Students in the Masters program, Department of Physical Therapy, University of Central Arkansas, Conway, AR.
Note: [***] Department of Physical Therapy, University of Central Arkansas, Conway, AR.
Note: [****] Address reprint requests to William D. Bandy, Department of Physical Therapy, University of Central Arkansas, Health Sciences Center, Suite 200, 201 Donaghey Avenue, Conway, Arkansas 72035-001.
Note: [*****] Department of Kinesiology, University of Central Arkansas, Conway, AR.
Abstract: The purpose of this study was to investigate the reliability and validity of inexperienced trained and inexperienced untrained testers in the use of skinfold calipers. The subjects consisted of five testers. One tester was experienced, having performed skinfold assessments for 17 years. Two testers were inexperienced with a skinfold caliper but were trained by the experienced tester in one half-hour session, whereas the remaining two testers were inexperienced and untrained, having read instructions only. Testers took skinfold measurements at three sites on 57 volunteers. Twenty-eight volunteers were tested twice to provide intratester reliability estimates. Intraclass correlations were used to evaluate intratester reliability of all testers, as well as intertester reliability between the trained testers and untrained testers to the experienced tester at each measurement site. Intratester reliability was greater with the experienced and trained testers than with the untrained testers. Intertester reliability of trained testers correlated more highly with the experienced tester (0.86–0.97) than did the untrained testers with the experienced tester (0.27–0.78). The results of this study indicate a substantial benefit of training to the clinician striving to become proficient in the use of skinfold calipers.
Keywords: Skinfold measurements, trained and untrained testers, reliability
DOI: 10.3233/IES-1994-4402
Journal: Isokinetics and Exercise Science, vol. 4, no. 4, pp. 137-140, 1994
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]